What does DIN EN ISO 14175 cover?
DIN EN ISO 14175 “Welding consumables – Gases and gas mixtures for fusion welding and allied processes” classifies shielding, backing and process gases into groups according to their chemical behaviour. The valid edition is ISO 14175:2008, which was confirmed in 2023. It superseded the former EN 439, whose designations were considerably more general.
The main groups at a glance
| Group | Behaviour | Composition (simplified) |
|---|---|---|
| I | inert | Argon, helium or argon-helium mixtures |
| M1, M2, M3 | oxidizing (mixed gases) | Argon with CO₂ and/or O₂; the oxidizing share increases from M1 to M3 |
| C | strongly oxidizing | pure CO₂ or CO₂ with oxygen |
| R | reducing | Argon with hydrogen |
| N | low reactivity | Nitrogen or nitrogen-containing mixtures |
| O | oxidizing | Oxygen |
| Z | – | Mixtures outside the specified ranges |
The exact limit values of each subgroup are given in the table below.
How to read the designation
A gas is designated by the standard number, group, chemical symbols and proportions, for example: ISO 14175 – M21 – ArC – 18
- M21: mixed gas of subgroup M2/1 (15 to 25 % CO₂ in argon)
- ArC: components argon and CO₂
- 18: nominal percentage of the additional gas, here 18 % CO₂, balance argon
Classification of process gases
| Symbol | Components in volume percent (nominal) | ||||||
|---|---|---|---|---|---|---|---|
| Main | Under- | oxidizing | inert | reducing | low reactivity | ||
| group | group | CO2 | O2 | Ar | He | H2 | N2 |
| I | 1 | 100 | |||||
| 2 | 100 | ||||||
| 3 | Rest | 0.5≤He≤95 | |||||
| M1 | 1 | 0.5≤CO2≤5 | Rest | 0,5≤H2≤5 | |||
| 2 | 0.5≤CO2≤5 | Rest | |||||
| 3 | 0,5≤O2≤3 | Rest | |||||
| 4 | 0.5≤CO2≤5 | 0,5≤O2≤3 | Rest | ||||
| M2 | 0 | 5≤CO2≤15 | Rest | ||||
| 1 | 15≤CO2≤25 | Rest | |||||
| 2 | 3≤O2≤10 | Rest | |||||
| 3 | 0.5≤CO2≤5 | 3≤O2≤10 | Rest | ||||
| 4 | 5≤CO2≤15 | 0,5≤O2≤3 | Rest | ||||
| 5 | 5≤CO2≤15 | 3≤O2≤10 | Rest | ||||
| 6 | 15≤CO2≤25 | 0,5≤O2≤3 | Rest | ||||
| 7 | 15≤CO2≤25 | 3≤O2≤10 | Rest | ||||
| M3 | 1 | 25≤CO2≤50 | Rest | ||||
| 2 | 10≤O2≤15 | Rest | |||||
| 3 | 25≤CO2≤50 | 2≤O2≤10 | Rest | ||||
| 4 | 5≤CO2≤25 | 10≤O2≤15 | Rest | ||||
| 5 | 25≤CO2≤50 | 10≤O2≤15 | Rest | ||||
| C | 1 | 100 | |||||
| 2 | Rest | 0,5≤O2≤30 | |||||
| R | 1 | Rest | 0,5≤H2≤15 | ||||
| 2 | Rest | 15≤H2≤50 | |||||
| N | 1 | 100 | |||||
| 2 | Rest | 0,5≤N2≤5 | |||||
| 3 | Rest | 5≤N2≤50 | |||||
| 4 | Rest | 0,5≤H2≤10 | 0,5≤N2≤5 | ||||
| 5 | 0,5≤H2≤50 | Rest | |||||
| O | 1 | 100 | |||||
| Z | Mixed gases with components not listed in the table or mixed gases with a Composition outside the specified ranges. |
Which shielding gas for DURMAT® materials?
Many DURMAT® cored wires are self-shielded and are welded as “open arc” without additional shielding gas; for this purpose, the powder filling contains its own shielding gas formers or provides a protective, covering slag layer. These wires carry the suffix “OA” for open arc in the product name. In submerged arc welding, the welding flux protects the weld pool. Recommendations for the welding flux can be found in the respective data sheets. For product groups processed with shielding gas, the recommended gas group according to DIN EN ISO 14175 is generally M13 or M21 for iron-based wires, I1 for nickel-based and cobalt-based wires without hard particles, and M13 for nickel-based wires of type Ni20 with hard particles. The shielding gas recommendation in the respective data sheet must always be observed.
Frequently asked questions
What is the difference between M21 and C1?
M21 is a mixed gas of argon with 15 to 25 % CO₂. C1 is pure CO₂.
Which standard applied before ISO 14175?
EN 439. Its group designations such as M21 live on in ISO 14175, but are supplemented there by the exact composition.
What does group Z mean?
Mixtures with components not listed in the table, or with proportions outside the specified ranges.
Questions about processing our filler materials? Our application engineers will help: +49 2154 4837-0 · info@durum.de